فایل فردا

مرجع دانلود فایل های دانشجویی

فایل فردا

مرجع دانلود فایل های دانشجویی

پیاده­ سازی و تحلیل مبدل DC-DC بهبود یافته رزنانسی با بار سری و عملیات فوق رزنانسی برای شارژر های باتری

شارژر باتری، مبدل رزنانسی با بار سری
دسته بندی مقالات ترجمه شده isi
بازدید ها 2
فرمت فایل doc
حجم فایل 2879 کیلو بایت
تعداد صفحات فایل 14
پیاده­ سازی و تحلیل مبدل DC-DC بهبود یافته رزنانسی با بار سری و عملیات فوق رزنانسی برای شارژرهای باتری

فروشنده فایل

کد کاربری 1055
کاربر

Novel Transformerless Grid-Connected Power Converter With Negative Grounding for Photovoltaic Generation System

Abstract—This paper proposes a novel transformerless gridconnected
power converter with negative grounding for a photovoltaic
generation system. The negative terminal of the solar cell
array can be directly connected to the ground in the proposed
grid-connected power converter to avoid the transparent conducting
oxide corrosion that occurs in some types of thin-film solar cell
array. The proposed grid-connected power converter consists of a
dc–dc power converter and a dc–ac inverter. The salient features
of the proposed power converter are that some power electronic
switches are simultaneously used in both the dc–dc power converter
and dc–ac inverter, and only two power electronic switches
operate at high switching frequency at the same time (one is in the
dc–dc power converter and the other is in the dc–ac inverter). The
leakage current of the photovoltaic generation system is reduced
because the negative terminal of the solar cell array is connected
directly to the ground. Finally, a prototype was developed to verify
the performance of the proposed grid-connected power converter.
The experimental results show that the performance of the proposed
grid-connected power converter is as expected..

پیاده­ سازی و تحلیل مبدل DC-DC بهبود یافته رزنانسی با بار سری و عملیات فوق رزنانسی برای شارژرهای باتری

چکیده

مبدل­های رزنانسی به دلیل داشتن مزایای مشخص از جمله ساد­گی ساختار مداری، سهولت طرح کنترلی، تلفات سوئیچینگ پایین و تداخل الکترومغناطیسی کم و غیره، توجه زیادی را به خود جلب کرده­اند. در این مقاله، یک شارژر باتری بسیار موثر با یک مبدل بهبود یافته رزنانسی با بار سری ساخته می­شود که برای کاربردهایی در انرژی تجدیدپذیر و به منظور بهبود عملکرد مدارهای شارژر حالت سوئیچینگ معمولی به کار برده می­شود. فرکانس سوئیچینگ شارژر باتری بهبودیافته رزنانسی با بار سری در حالت هدایت پیوسته قرار داشت. حالت­های عملیاتی مدار از روی پروفیل­های هدایت تعیین می­شوند. معادلات عملیاتی و تئوری عملیاتی نیز ایجاد شدند. این مقاله، با استفاده از تقریب موج اصلی و یک مدار معادل باتری به ساده­سازی آنالیز مدار می­پردازد. متوسط بازده شارژ[1] ساختار پیشنهادی بالا بوده و برابر با 87.5% است.


الگوریتم جدید به منظور تعیین مکان خطا در خطوط انتقال بلند جبران­سازی شده با استفاده از ادوات FACTS سری

مدل خط با پارامتر گسترده، محل خط، دستگاه سیستم­های انتقال ac انعطاف­پذیر (FACTS)، نمونه­برداری سنکرون، حوزه زمان
دسته بندی مقالات ترجمه شده isi
بازدید ها 3
فرمت فایل doc
حجم فایل 687 کیلو بایت
تعداد صفحات فایل 14
الگوریتم جدید به منظور تعیین مکان خطا در خطوط انتقال بلند جبران­سازی شده با استفاده از ادوات FACTS سری

فروشنده فایل

کد کاربری 1055
کاربر

A Novel Fault-Location Algorithm for Long Transmission Lines Compensated by Series FACTS Devices

Abstract—This paper introduces a new noniterative fault-location
algorithm for long transmission lines compensated by a series
flexible ac transmission systems (FACTS) device. In the proposed
algorithm, synchronous voltage and current samples from both
ends of the transmission line are used and the distributed parameter
line model in the time domain is applied. Due to the difficulties
in the modeling of the series FACTS devices during a fault, the presented
method does not use the model of the series devices. In this
paper, the fault-location problem is converted to an optimization
one in which the location and resistance of the fault are the decision
variables. The proposed method includes three stages. Two fault locations
are obtained, corresponding to the first two stages. In stage
three, the obtained results from stages 1 and 2 are compared, and
the correct fault location is selected. The proposed algorithm is a
noniterative one and it is suitable for transmission lines compensated
by any series FACTS device which could have the overvoltage
protection and can be in any operating mode. The performance of
the proposed algorithm is evaluated under different structural and
fault conditions. The simulation results confirm the accuracy of the
proposed algorithm

الگوریتم جدید به منظور تعیین مکان خطا در خطوط انتقال بلند جبران­سازی شده با استفاده از ادوات FACTS سری

چکیده

در این مقاله، یک الگوریتم غیرتکراری جدید برای تعیین محل خطا در خطوط انتقال بلند جبران­سازی شده با استفاده از تجهیزات سیستم­های انتقال acانعطاف­پذیر (FACTS) سری معرفی می­شود. در این الگوریتم، نمونه­برداری­های ولتاژ و جریان سنکرون از هر دو سمت خط انتقال بکار برده شده است و پارامتر توزیعی (گسترده) مدل خط در حوزه زمان استفاده شده است. با توجه به دشواری مدل­سازی ادوات FACTS سری در زمان خطا، روش پیشنهادی از مدل ادوات سری استفاده نمی­کند. در این مقاله، مساله تعیین محل خطا به مساله بهینه­سازی تبدیل شده است که در آن مکان و مقاومت خطا متغیرهای تصمیم­گیری هستند. روش پیشنهادی شامل سه مرحله است. دو محل خطا بدست آورده می­شود که به دو مرحله­ی اول مربوط هستند. در سومین مرحله، نتایج به­دست آمده از مراحل 1 و 2 مقایسه می­شوند، و محل دقیق خطا انتخاب می­شود. الگوریتم پیشنهادی نوعی الگوریتم غیرتکراری است و برای خطوط انتقال بلند جبران­سازی شده با هر دستگاه FACTS سری مناسب است که دارای حفاظت در برابر اضافه­ولتاژ بوده و می­تواند در هر حالت عملیاتی قرار داشته باشد. عملکرد الگوریتم پیشنهادی تحت شرایط مختلف از نظر ساختاری و خطا بررسی می­شود. نتایج شبیه­سازی دقت الگوریتم ارائه شده را تایید می­کند.

.


میرائی نوسانات میان­ ناحیه­ ای با استفاده از طرح­ های جبران­ساز سری نامتعادل فازی

کنترلرهای FACTS، جبران­ساز سری مرکب، نوسانات میان­­ناحیه­ای، نامتعادلی فاز، پایداری سیستم قدرت، جبران­ساز سری، جبران ساز استاتیکی سری سنکرون، خازن سری کنترل­شده با تریستور
دسته بندی مقالات ترجمه شده isi
بازدید ها 8
فرمت فایل doc
حجم فایل 1585 کیلو بایت
تعداد صفحات فایل 11
میرائی نوسانات میان­ ناحیه­ ای با استفاده از طرح­ های جبران­ساز سری نامتعادل فازی

فروشنده فایل

کد کاربری 1055
کاربر

Damping Inter-Area Oscillations Using Phase Imbalanced Series Compensation Schemes

Abstract—The recently proposed phase imbalanced series capacitive
compensation concept has been shown to be effective in enhancing
power system dynamics as it has the potential of damping
power swing as well as subsynchronous resonance oscillations. In
this paper, a comparative effectiveness of two “hybrid” series capacitive
compensation schemes in damping inter-area oscillations
is evaluated. A hybrid scheme is a series capacitive compensation
scheme, where two phases are compensated by fixed series capacitor
(C) and the third phase is compensated by either a TCSC or
SSSC in series with a fixed capacitor