Novel Transformerless Grid-Connected Power Converter With Negative Grounding for Photovoltaic Generation System
Abstract—This paper proposes a novel transformerless gridconnected
power converter with negative grounding for a photovoltaic
generation system. The negative terminal of the solar cell
array can be directly connected to the ground in the proposed
grid-connected power converter to avoid the transparent conducting
oxide corrosion that occurs in some types of thin-film solar cell
array. The proposed grid-connected power converter consists of a
dc–dc power converter and a dc–ac inverter. The salient features
of the proposed power converter are that some power electronic
switches are simultaneously used in both the dc–dc power converter
and dc–ac inverter, and only two power electronic switches
operate at high switching frequency at the same time (one is in the
dc–dc power converter and the other is in the dc–ac inverter). The
leakage current of the photovoltaic generation system is reduced
because the negative terminal of the solar cell array is connected
directly to the ground. Finally, a prototype was developed to verify
the performance of the proposed grid-connected power converter.
The experimental results show that the performance of the proposed
grid-connected power converter is as expected..
پیاده سازی و تحلیل مبدل DC-DC بهبود یافته رزنانسی با بار سری و عملیات فوق رزنانسی برای شارژرهای باتری
چکیده
مبدلهای رزنانسی به دلیل داشتن مزایای مشخص از جمله سادگی ساختار مداری، سهولت طرح کنترلی، تلفات سوئیچینگ پایین و تداخل الکترومغناطیسی کم و غیره، توجه زیادی را به خود جلب کردهاند. در این مقاله، یک شارژر باتری بسیار موثر با یک مبدل بهبود یافته رزنانسی با بار سری ساخته میشود که برای کاربردهایی در انرژی تجدیدپذیر و به منظور بهبود عملکرد مدارهای شارژر حالت سوئیچینگ معمولی به کار برده میشود. فرکانس سوئیچینگ شارژر باتری بهبودیافته رزنانسی با بار سری در حالت هدایت پیوسته قرار داشت. حالتهای عملیاتی مدار از روی پروفیلهای هدایت تعیین میشوند. معادلات عملیاتی و تئوری عملیاتی نیز ایجاد شدند. این مقاله، با استفاده از تقریب موج اصلی و یک مدار معادل باتری به سادهسازی آنالیز مدار میپردازد. متوسط بازده شارژ[1] ساختار پیشنهادی بالا بوده و برابر با 87.5% است.
دسته بندی | مقالات ترجمه شده isi |
بازدید ها | 3 |
فرمت فایل | doc |
حجم فایل | 687 کیلو بایت |
تعداد صفحات فایل | 14 |
A Novel Fault-Location Algorithm for Long Transmission Lines Compensated by Series FACTS Devices
Abstract—This paper introduces a new noniterative fault-location
algorithm for long transmission lines compensated by a series
flexible ac transmission systems (FACTS) device. In the proposed
algorithm, synchronous voltage and current samples from both
ends of the transmission line are used and the distributed parameter
line model in the time domain is applied. Due to the difficulties
in the modeling of the series FACTS devices during a fault, the presented
method does not use the model of the series devices. In this
paper, the fault-location problem is converted to an optimization
one in which the location and resistance of the fault are the decision
variables. The proposed method includes three stages. Two fault locations
are obtained, corresponding to the first two stages. In stage
three, the obtained results from stages 1 and 2 are compared, and
the correct fault location is selected. The proposed algorithm is a
noniterative one and it is suitable for transmission lines compensated
by any series FACTS device which could have the overvoltage
protection and can be in any operating mode. The performance of
the proposed algorithm is evaluated under different structural and
fault conditions. The simulation results confirm the accuracy of the
proposed algorithm
الگوریتم جدید به منظور تعیین مکان خطا در خطوط انتقال بلند جبرانسازی شده با استفاده از ادوات FACTS سری
چکیده
در این مقاله، یک الگوریتم غیرتکراری جدید برای تعیین محل خطا در خطوط انتقال بلند جبرانسازی شده با استفاده از تجهیزات سیستمهای انتقال acانعطافپذیر (FACTS) سری معرفی میشود. در این الگوریتم، نمونهبرداریهای ولتاژ و جریان سنکرون از هر دو سمت خط انتقال بکار برده شده است و پارامتر توزیعی (گسترده) مدل خط در حوزه زمان استفاده شده است. با توجه به دشواری مدلسازی ادوات FACTS سری در زمان خطا، روش پیشنهادی از مدل ادوات سری استفاده نمیکند. در این مقاله، مساله تعیین محل خطا به مساله بهینهسازی تبدیل شده است که در آن مکان و مقاومت خطا متغیرهای تصمیمگیری هستند. روش پیشنهادی شامل سه مرحله است. دو محل خطا بدست آورده میشود که به دو مرحلهی اول مربوط هستند. در سومین مرحله، نتایج بهدست آمده از مراحل 1 و 2 مقایسه میشوند، و محل دقیق خطا انتخاب میشود. الگوریتم پیشنهادی نوعی الگوریتم غیرتکراری است و برای خطوط انتقال بلند جبرانسازی شده با هر دستگاه FACTS سری مناسب است که دارای حفاظت در برابر اضافهولتاژ بوده و میتواند در هر حالت عملیاتی قرار داشته باشد. عملکرد الگوریتم پیشنهادی تحت شرایط مختلف از نظر ساختاری و خطا بررسی میشود. نتایج شبیهسازی دقت الگوریتم ارائه شده را تایید میکند.
.
دسته بندی | مقالات ترجمه شده isi |
بازدید ها | 8 |
فرمت فایل | doc |
حجم فایل | 1585 کیلو بایت |
تعداد صفحات فایل | 11 |
Damping Inter-Area Oscillations Using Phase Imbalanced Series Compensation Schemes
Abstract—The recently proposed phase imbalanced series capacitive
compensation concept has been shown to be effective in enhancing
power system dynamics as it has the potential of damping
power swing as well as subsynchronous resonance oscillations. In
this paper, a comparative effectiveness of two “hybrid” series capacitive
compensation schemes in damping inter-area oscillations
is evaluated. A hybrid scheme is a series capacitive compensation
scheme, where two phases are compensated by fixed series capacitor
(C) and the third phase is compensated by either a TCSC or
SSSC in series with a fixed capacitor