آزمایش شروع تخلیه جزئی در موتور های ولتاژ پایین

MG1 Part 31، عایق موتور، ولتاژ شروع تخلیه جزئی (PDIV)
دسته بندی مقالات ترجمه شده isi
بازدید ها 8
فرمت فایل doc
حجم فایل 1122 کیلو بایت
تعداد صفحات فایل 13
آزمایش شروع تخلیه جزئی در موتورهای ولتاژ پایین

فروشنده فایل

کد کاربری 1055
کاربر

Partial-Discharge-Inception Testing on Low-Voltage Motors

Abstract—This is a review of one manufacturer’s efforts
toward testing National Electrical Manufacturers Association
(NEMA) low-voltage motor insulation for compatibility with
adjustable-speed drives (ASDs). Partial-discharge-inceptionvoltage
(PDIV) measurements were selected as a tool to evaluate
the future performance of the stator insulation system to resist
deterioration by the drives. PDIV measurement is explained in
terms of procedure and accuracy. Data are presented from tests
made on motors from several prominent manufacturers

آزمایش شروع تخلیه جزئی در موتورهای ولتاژ پایین

چکیده

این مقاله مروری بر تلاش های یکی از سازندگان در جهت آزمایش عایقی موتور ولتاژ پایین انجمن ملی سازندگان الکتریکی (NEMA) جهت سازگاری با درایوهای سرعت متغیر (ASDs) می باشد. اندازه گیری های ولتاژ شروع تخلیه جزئی (PDIV) بعنوان ابزاری جهت ارزیابی عملکرد آتی سیستم عایقی استاتور برای مقابله در برابر تخریب درایوها انتخاب گردید. اندازه گیری PDIV برحسب طرز کار و دقت توضیح داده می شود. اطلاعاتی از آزمایش های انجام شده بر روی موتورها از چندین سازنده شناخته شده ارائه داده می شود.

.


اثر ارتعاش مکانیکی بر رفتار تخلیه­ های جزئی در سیم پیچی های ژنراتور

تخلیه های جزئی، ارتعاش، ژنراتور، سیم پیچ
دسته بندی مقالات ترجمه شده isi
بازدید ها 5
فرمت فایل doc
حجم فایل 547 کیلو بایت
تعداد صفحات فایل 12
اثر ارتعاش مکانیکی بر رفتار تخلیه­ های جزئی در سیم پیچی های ژنراتور

فروشنده فایل

کد کاربری 1055
کاربر

Effect of Mechanical Vibration on the Behavior of Partial Discharges in Generator Windings

ABSTRACTAs mechanical vibration usually exists in HV motors and generators, its influence on the
partial discharge (PD) needs to be studied so as to improve the reliability of on-line PD
monitoring method. In this report, the mechanical vibration frequency was synchronized
to the power frequency and the effects of vibration phase and frequency were
investigated. Because the length of the discharge gap changed with the vibration, obvious
variation in the slot-PD patterns was observed at different vibration lead phase and
frequency. Moreover, when the vibration amplitude was large, it was also found that the
PD behavior at low voltage just above the PD inception voltage was different from that at
higher voltage. This was explained in terms of the effects of the field variation in the gap
due to the vibration and the charges left on the insulating surface due to PD.

اثر ارتعاش مکانیکی بر رفتار تخلیه­ های جزئی در سیم پیچی های ژنراتور

چکیده

از آنجائیکه ارتعاش مکانیکی در موتورها و ژنراتورهای HV وجود دارد، لازم هست تا تاثیر آن بر تخلیه جزئی (PD) مورد مطالعه قرار گیرد تا قابلیت اعتماد روش نظارت آنلاین PD بهبود یابد. در این مقاله، فرکانس نوسان مکانیکی با فرکانس قدرت سنکرون شده است و اثرات فرکانس و فاز نوسان مورد بررسی قرار گرفت. بخاطر اینکه طول شکاف تخلیه متناسب با ارتعاش تغییر می کند، ارتعاش آشکارا در الگوهای شیار-PD در ارتعاش پیشفاز و فرکانس مختلف مشاهده گردید. بعلاوه، زمانیکه دامنه ارتعاش بزرگ باشد، مشاهده می گردد که رفتار PD در ولتاژ پایین بالاتر از ولتاژ شروع PD متفاوت از همان ولتاژ بالا می باشد. این بر حسب اثرات تغییر میدان در شکاف بخاطر ارتعاش و بارهایی که در سطح عایقی بخاطر PD باقی مانده توضیح داده شد.